Translate

2024年4月7日星期日

Perkins 2806F Engine Solenoid Valve (DEF Heater Coolant)-Remove and Install Guide

This article introduces Perkins 2806F Engine Solenoid Valve (DEF Heater Coolant)-Remove and Install

2023A& 2022A Perkins EST Electronic Service Tool Diagnostic Software Full Provide Installation Service


Removal Procedure:
NOTICE Care must be taken to ensure that fluids are con-
tained during performance of inspection, mainte-
nance, testing, adjusting and repair of the product.
Be prepared to collect the fluid with suitable contain-
ers before opening any compartment or disasslem-
bling any component containing fluids.
Dispose of all fluids according to local regulations and mandates.

NOTICE:

Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened component life.

1. Turn the battery disconnect switch to the OFF position.
2. Drain the coolant from the cooling system into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant -Change"for the correct procedure.



 Perkins Engine ECM ECU Flash Files Collection Download

  3. Disconnect harness assembly (1) from solenoid valve (2).
4. Loosen clamp hoses (6). Disconnect hose assembly (5) from solenoid valve (2).
5. Loosen clamp hoses (3). Disconnect hose assembly (4) from solenoid valve (2).
6. Remove bolts (7) and remove solenoid valve (2) from bracket (9).
Note: Note the orientation of the solenoid valve.
7. If necessary, follow Step 2. bthrough Step 7.b in order to remove bracket (9).
a. Remove bolts (8) from bracket (9).
b. Remove bracket (9) from the Diesel Emission Fluid (DEF) tank assembly.

 

Installation Procedure
Care must be taken to ensure that fluids are con- tained during performance of inspection, mainte- nance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable contain- ers before opening any compartment or disassem- bling any component containing fluids.

Dispose of all fluids according to local regulations and mandates.

NOTICE

Keep all parts clean from contaminants.

Contaminants may cause rapid wear and shortened component life.

1. Ensure that all components are clean and free

from wear and damage. If necessary, replace any components that are worn or damaged.






Typical example

2. If necessary, follow Step 2.a through Step 2.b in order to install bracket (9).

a. Position bracket (9) onto the DEF tank assembly.

b. Install bolts to bracket (9). Tighten the bolts to a torque of 9 N·m (80 lb in).

3. Position solenoid valve (2) to bracket (9). Ensure that the valve is correctly orientated.

4. Install bolts (4) to solenoid valve (2). Tighten the bolts to a torque of 9 N·m (80 lb in).

5. Connect hose assembly (5) to solenoid valve (2). Securely clamp hoses (6).

6. Connect hose assembly (4) to solenoid valve (2). Securely clamp hoses (3).

7. Connect harness assembly (1) to solenoid valve

8. Fill the cooling system with coolant. Refer to

Operation and Maintenance Manual, “Cooling

System Coolant - Change” for the correct

procedure.

9. Turn the battery disconnect switch to the ON
Perkins EST Diagnostic Adapter-High Quality
position.


没有评论:

发表评论

How to relieve hydraulic pressure in the hydraulic circuit of a CAT excavator.

  How to relieve hydraulic pressure in the hydraulic circuit of 312D2 and 313D2 excavators   Steps to relieve pressure:   Caterpillar ET 202...