Translate

2022年8月2日星期二

Introduces Perkins 2806F Engine Air Cleaner-Remove and Install

   This article mainly Introduces Perkins 2806F Engine Air Cleaner-Remove and Install


Perkins Engine ECM Flash File Download

Removal Procedure
.NOTICE Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened component life.


Perkins SPI2 VERSION 2018A Service & Parts CATALOGUE SOFTWARE


1. For the location of the assembly of air cleaner(5).
Refer to Original Equipment Manufacturer (OEM)
for the correct location.
2. Loosen hose clamp(11) for hose assembly(12).
3. Attach a suitable lifting device to support the weight of air cleaner assembly (5). The weight of the air cleaner is approximately 23kg (51 lb).
4. Remove bolts (6) from air cleaner(5).
5. Use the suitable lifting device to remove air cleaner assembly(7) from the OEM bracket and the turbocharger.
6. If necessary, follow Step 6.a through Step 6.f to disassemble the assembly of air cleaner(5).
a. Position air cleaner (5) onto a suitable support.
b. Loosen clamp(2) and remove pre-cleaner(1)
from expansion adapter(3).
c. Loosen clamp(4) and remove expansion adapter(3).
d. Loosen hose clamps(11) for hose assembly
(10). Remove the hose assembly from tube assembly(9).
e. If necessary, remove indicator (10) from tube assembly(9).
f. Loosen hose clamps(7) for hose assembly(8). Remove the hose assembly from air cleaner(5)
and tube assembly(9).


Installation Procedure
        

Function 2020aPerkins EST Electronic Service Tool Diagnostic Software Full



2. If necessary, follow Step 2.a through Step 2. ito assemble the assembly of air cleaner(5).
a. Position air cleaner(5) onto a suitable support.
b. Apply Tooling (A) to hose assembly(8) and hose assembly(12).
c. Install hose assembly(8) onto air cleaner(5).
Ensure hose clamps (7) are correctly orientated.d. Install tube assembly (9) to hose assembly(8).
Ensure that the tube assembly is correctly orientated. Tighten the hose clamps to a torque of 8N-m(71lb in).
e. Installindicator(10) to tube assembly(9).
Securely tighten the indicator.
f. Install hose assembly(10) to tube assembly(9).
Ensure hose clamps(11) are correcty orientated. Tighten the hose clamp to a torque of 8N-m(71ib in).
g. Install expansion adapter (3) onto air cleaner
(5). Ensure clamp(4) is correctly orientated and seated onto the air cleaner. Securely tighten the clamp.
h. Install pre-cleaner(1) to expansion adapter(3).
Securely tighten clamp(2).
i. If air cleaner(5) has been disassembled, hose clamps(11) will need tightening after the air cleaner assembly has been installed.
3. Attach a suitable lifting device to support the weight of air cleaner assembly(5). The weight of the air cleaner is approximately 23kg(51 lb).
4. Use the suitable lifting device to install air cleaner assembly(7) onto the OEM bracket and the turbocharger.
5. Install bolts (6) to air cleaner(5) and the OEM bracket. Tighten the bolts, refer to the OEM for the correct tightening value.
6. Tighten hose clamp(11) for hose assembly(12) to a torque of8 N-m (71 lb in).
7. If necessary, replace air cleaner element for air cleaner assembly(5). Refer to Operation and Maintenance Manual, Engine Air Cleaner Element
-Replace for the correct procedure.