How to adjust the JCB loader valve adjustment

 This article explains how to adjust the valve adjustment on a JCB loader

 


Note: If a new regulator valve is fitted, or a valve stripped, 
 
cleaned and rebuilt, then the pressure spool should be 
 
backed off to a low pressure. This will prevent inadvertent 
 
damage to the pump.
 

Flow Regulator Spool 
 
The pressure in the pump out line (pressure test connector 
 
B) should be 20 bar (290 lbf/in2) greater than the pressure in 
 
the load sense line (pressure test connector A). If not adjust 
 
 
the regulator flow spool as described below: 
 
1
Lower the backhoe bucket and loader shovel to rest on
the ground; stop the engine; operate the control levers
to vent residual hydraulic pressure. 
 
2
Gain access to the regulator valve assembly (mounted
on the pump). 
 
3
Remove cap C and loosen locknut D
 
4
Turn adjusting screw E clockwise to increase pressure
setting and anti-clockwise to decrease setting. 
 
5
Repeat pressure test as detailed previously and
establish valve is set correctly. 
 
6
Tighten locknut, refit cap
 
 